HHS Wants Annual Pentests in the HIPAA Security Rule. Here's What That Looks Like.

HHS proposed updates to the HIPAA Security Rule in early 2025 that would make penetration testing an explicit requirement for covered entities. Here's what the proposed rule says and how to prepare.

DevSecCode Team · · Compliance · 9 min read

The HIPAA Security Rule Is Getting Specific About Pentesting

The Department of Health and Human Services (HHS) published a Notice of Proposed Rulemaking (NPRM) for the HIPAA Security Rule in January 2025 that would significantly expand technical testing requirements for covered entities and business associates. The most notable addition: explicit penetration testing requirements.

The current HIPAA Security Rule (45 CFR 164.308(a)(8)) requires periodic "technical and nontechnical evaluation" of security controls. The word "penetration testing" does not appear in the current rule. The proposed revision would add specific requirements for vulnerability scanning and penetration testing as distinct, required activities.

What the Proposed Rule Requires

Vulnerability Scanning

The NPRM proposes that covered entities and business associates run automated vulnerability scans at least every six months, or more often if their risk analysis calls for it. That moves beyond the current ambiguous "evaluation" language.

Penetration Testing

The NPRM proposes penetration testing at least every 12 months, or more often if your risk analysis calls for it, as a required (not addressable) implementation specification, carried out by a qualified person.

Why This Matters for Development Teams

The proposed text doesn't single out application-layer testing, but healthcare applications that process ePHI belong in what these tests cover. In practice:

  1. Custom-built healthcare applications need both SAST and DAST coverage
  2. FHIR API implementations are natural targets for a penetration test
  3. Patient portals are internet-facing ePHI systems, the highest priority for testing
  4. Internal clinical tools that access ePHI are also in scope

The Application Pentest Gap

Most healthcare penetration tests focus on network infrastructure: perimeter scanning, firewall rules, VPN configurations. Scoping tests to relevant electronic information systems would bring ePHI applications into them, which closes a gap that has been obvious to security practitioners for years.

Healthcare application vulnerabilities (SQL injection in patient search, broken authentication in API gateways, IDOR in patient record endpoints) are common penetration test findings. The largest breaches can start elsewhere: Change Healthcare (2024) began with stolen credentials on a remote access portal without MFA, and Ascension (2024) with an employee downloading a malicious file. A test program has to cover both.

The Cost Pressure

Healthcare organizations already face significant compliance costs. The proposed pentesting requirement adds operational expense. Qualified pentesters are expensive, and annual testing of all relevant ePHI systems, applications included, is a meaningful scope expansion.

This creates economic pressure for continuous security testing that reduces pentest scope. If an organization can demonstrate continuous vulnerability scanning with documented remediation throughout the year, the annual pentest validates the process rather than discovering months of accumulated vulnerabilities.

Preparing Now

The comment period closed in March 2025, and HHS's regulatory agenda reportedly projects final action no earlier than July 2027, so the final text and timing remain uncertain. Organizations that implement continuous scanning and application-layer security testing now will be positioned for compliance when the final rule takes effect.

How Deva Addresses Healthcare Pentest Requirements

Deva's HIPAA mapping, currently in preview, ties findings to Security Rule controls on Pro. On Pro, with scan-on-save enabled in the editor extension, Deva keeps a local history of scans, which supports a compliance program but does not satisfy a requirement by itself.

For organizations subject to the proposed scanning cadence (every six months), Deva's evidence export on Pro produces signed scan records. SARIF output is a separate, unsigned format for tooling.

The local model matters here more than anywhere: ePHI code patterns, patient data in test fixtures, and clinical workflow logic stay on the developer's machine. No healthcare-specific context traverses an external API.

Frequently asked questions

Does HIPAA require penetration testing?
The current HIPAA Security Rule (45 CFR 164.308(a)(8)) requires periodic 'technical and nontechnical evaluation' of security controls but does not name penetration testing explicitly. HHS's 2025 NPRM proposes adding annual penetration testing as an explicit, required (not addressable) implementation specification.
What is the HHS NPRM and when does it take effect?
The Notice of Proposed Rulemaking was published in January 2025. Comments closed on March 7, 2025, and as of November 2026 the rule is not final. Regardless of the exact final language, the direction is prescriptive security testing, so organizations preparing now will be positioned for compliance when the final rule takes effect.
How often does the proposed HIPAA rule require vulnerability scans?
The NPRM proposes automated vulnerability scans at least every six months, or more often if your risk analysis calls for it.
Are FHIR APIs in scope for HIPAA pentest requirements?
The NPRM doesn't name FHIR. It applies to relevant electronic information systems, so a FHIR API that handles ePHI is a reasonable part of a test's scope, as are patient portals and internal clinical tools.

Related glossary terms